1 | Enclosure | 2MM BKHD/DECK Mounted; IP52 Mentioned Otherwise. MS/SS316/Aluminium |
2 | Working Voltage | 24VDC &24VDC FOR Plc/Controls |
3 | No. Of Supply Sources | Two; Combinaton Of Genset-Ac & Battery-Dc |
4 | No. Of Light Circuits | 8 Or 16 Or 24 - As Reuired Single Or Double Decker Lights |
5 | Operating Features | Supply Auto Change Over Upon Failure Light Auto Change/Alarm Upon Fail Current Measurement Of Each Lamp Data Logging & Daily Logs Etc For Each Light. Provision For Communication And Control By IPMS Through RS485 Link. Time Of The Dat/Sunlight Based Operation (Option) Group Operation Of Lamps Based On Location/Operational Status Of Vessel (Programmable) |
6 | Controller For Logic | PLCs With HMI For Alarm, Communication & Control |
7 | Facilities & Utilities Inbuilt Into The System | Audible & Visible Alarms For All Failures Group Operations Automatic Change Over Of Supply And Lights Upon Failure Datalogging Integration With IPMS Current Sensing Using Hall Effect Devices Hence No Voltage Drop For DC Light Circuits |
8 | Communication & Control | Optional RS485 Between The Panel & Manned Control Stations- Remote Operation By Scada/IPMS |